Key Advantages
Integrated design simplifies installation and O&M. Modular architecture enables flexible capacity expansion
2.8㎡
↓ 10%
Footprint
522kWh~3.13MWh
Capacity Range
- Footprint: 2.8㎡ ↓ 10%
- Capacity Range: 522kWh~3.13MWh
Intelligent monitoring and interlocks protect batteries in real time. Fire detection, gas suppression and built-in heating ensure rapid response and temperature control
≤3s
Alarm Response Time
≤30s
Heating Response Time
- Alarm Response Time: ≤3s
- Heating Response Time: ≤30s
Refined liquid cooling keeps cell temperature differentials within ≤2°C, while multiple modes reduce auxiliary power consumption
≤2℃
Cell Temperature Differential
↓ 20%
Aux. Power Consumption
≥90%
System RTE
- Cell Temperature Differential: ≤2℃
- Aux. Power Consumption: ↓ 20%
- System RTE: ≥90%
Remote OTA upgrades enable continuous optimization, with cloud-based monitoring and multi-device access
≤15 min
OTA Time / Unit
≤60s
Data Refresh Rate
- OTA Time / Unit: ≤15 min
- Data Refresh Rate: ≤60s
Applications
Commercial Buildings
Lower electricity costs through peak shaving;
backup power for critical loads;
improved energy efficiency.
improved energy efficiency.
Lower electricity costs through peak shaving;
backup power for critical loads;
improved energy efficiency.
improved energy efficiency.
PV-Storage-Charging Stations
Balance EV charging loads;
maximize PV self-consumption;
reduce charging costs;
prevent grid overload.
maximize PV self-consumption;
reduce charging costs;
prevent grid overload.
Balance EV charging loads;
maximize PV self-consumption;
reduce charging costs;
prevent grid overload.
maximize PV self-consumption;
reduce charging costs;
prevent grid overload.
Industrial Parks
Peak-valley arbitrage;
demand management;
uninterrupted production;
renewable energy integration.
demand management;
uninterrupted production;
renewable energy integration.
Peak-valley arbitrage;
demand management;
uninterrupted production;
renewable energy integration.
demand management;
uninterrupted production;
renewable energy integration.
Infrastructure
Backup power for reliable supply;
defer grid expansion;
support peak shaving and frequency regulation.
defer grid expansion;
support peak shaving and frequency regulation.
Backup power for reliable supply;
defer grid expansion;
support peak shaving and frequency regulation.
defer grid expansion;
support peak shaving and frequency regulation.
Microgrid
Balance distributed energy fluctuations;
power critical loads during islanded operation;
improve energy self-sufficiency.
power critical loads during islanded operation;
improve energy self-sufficiency.
Balance distributed energy fluctuations;
power critical loads during islanded operation;
improve energy self-sufficiency.
power critical loads during islanded operation;
improve energy self-sufficiency.